FLAMEX® PANTO LEAD-FREE 240mm²

Description

Description

Standards

  • Product
    EN 45545-2 (HL3); EN 50264-1; IEC 60502

For inside and outside use in railway vehicles. Installation in cable ducts or tubes.

Available on request: HV loop, completely pre-assembled flexible cables with plugs and sealing ends, electrically tested.

 

DESIGN

1. Conductor: Flexible stranded tinned copper, class 5 acc. to IEC 60228

2. Inner semi-conductive layer: Conductive rubber

3. Insulation: Cross-linked compound type EI 110 acc. to EN 50264-1

4. Outer conductive layer: Conductive rubber easy to strip

5. Screen: Conductive tape + tinned single wires with separator

6. Outer sheath: Cross-linked compound type EM104  acc. to EN 50264-1. Oil, diesel, ozone and UV resistant. Colour: black

 

Example of cable marking: FLAMEX PANTO – LEAD FREE - 1x [conductor nominal cross section] / [geometrical screen cross-section] 26/45kV I LYNXEO I WEEK/YEAR batch-no

FIRE SAFETY STANDARDS

FLAMEX® HV Power cables are conform to EN 45545-2


GUIDE TO USE

  • Cabling rules are given in EN 50343 and EN 50355
  • Permissible current carrying capacities: values and calculation method are given in EN 50343
  • Bending radius:
    • Static use: 5 x outer cable diameter
    • For installation and occasional movements: 10 x outer cable diameter

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Tin plated copper
Conductor flexibility
Flexible class 5
Material of the inner semi-conductor
conductive rubber
Insulation
Cross-linked compound
Material of the external semi-conductor
Conductive rubber
Screen
Tin plated copper wires
Outer sheath
Cross-linked compound
Halogen free
EN 60754-1 & EN 60684-2

Dimensional characteristics

Dimensional characteristics

Conductor cross-section
240 mm²
Screen section
25 mm²
Diameter over external semi-conductor
40.0 mm
Minimum outer diameter
45.0 mm
Maximum outer diameter
48.0 mm
Approximate weight
4300 kg/km

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
26 / 45 (54) kV
Maximum operating voltage
32 kV

Usage characteristics

Usage characteristics

Flame retardant
EN 60332-1-2
Fire retardant
IEC 60332-3-24 (cat C)
Smoke density
EN/IEC 61034-2
Gases toxicity
EN 50305-9.2
Operating temperature, range
-40 ... 90 °C
Fire load
11 kWh/m
Minimum operating temperature
-40 °C
Short-circuit max. conductor temperature
200 °C
Oil resistance
Yes
Ozone resistance
Yes
U.V resistance
Yes

Resources

Resources

Documentation

xls — 0 B
xlsx — 0 B

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close